Kinco FV20 Inverter: Inverters for 3-phase electric motors with three-phase supply, with vector control, built-in EMC filter, RS-485 MODBUS communication, 6 digital, 2 relay and 2 analog inputs and outputs. From now on, it is also equipped with 1 pulse output. 7 types of power design: 1500W (FV20-4T-0015G), 2200W (FV20-4T-0022G), 3700W (FV20-4T-0037G), 5500W (FV20-4T-0055G), 7500W (FV20-4T-0075G), 11000W (FV20-4T-0110G) and 15000W version (FV20-4T-0150G)


13product

Input: 380~ 440Vac, 3 phases
Output: 3 phases (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter< br />6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs ( 0-10V v 0-20mA)
Can be screwed onto a mounting plate
Power: 1.5KW
Output current: 3.7A

Expected delivery:
On stock
External stock H2 (1-3 days):
10 db
In stock: 1 pcs
External stock H2 (1-3 days): 10 db
Nettó: 180.89

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 2.2KW
Output current: 5.5A

Expected delivery:
On stock
External stock H2 (1-3 days):
3 db
In stock: 1 pcs
External stock H2 (1-3 days): 3 db
Nettó: 211.39

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 3.7KW
Output current: 8.8A

Expected delivery:
On stock
External stock H2 (1-3 days):
0 db
In stock: 1 pcs
External stock H2 (1-3 days): 0 db
RAKTÁRON
Nettó: 236.68

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 5.5KW
Output current: 13A

Expected delivery:
On stock
External stock H2 (1-3 days):
12 db
In stock: 1 pcs
External stock H2 (1-3 days): 12 db
Nettó: 261.99

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 7.5KW
Output current: 17A

Expected delivery:
On stock
External stock H2 (1-3 days):
6 db
In stock: 1 pcs
External stock H2 (1-3 days): 6 db
Nettó: 284.79

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 15KW
Output current: 32A

Expected delivery:
On stock
External stock H2 (1-3 days):
5 db
In stock: 1 pcs
External stock H2 (1-3 days): 5 db
Nettó: 421.84

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 18,5KW
Output current: 37A

Expected delivery:
1-2 working days
External stock H2 (1-3 days):
0 db
In stock: 1 pcs
External stock H2 (1-3 days): 0 db
Nettó: 514.97

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 22KW
Output current: 45A

Expected delivery:
1-2 working days
External stock H2 (1-3 days):
4 db
In stock: 1 pcs
External stock H2 (1-3 days): 4 db
Nettó: 703.92

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 30KW
Output current: 60A

Expected delivery:
On stock
External stock H2 (1-3 days):
2 db
In stock: 1 pcs
External stock H2 (1-3 days): 2 db
Nettó: 837.49

Bemenet: 380~ 440Vac, 3 fázis
Kimenet: 3 fázis (~ 230Vac)
Vektor szabályzás
RS485 Modbus RTU kommunikáció
Beépített EMC szűrő
6 db multifunkciós digitális bemenet
2 db programozható relé
1 db impulzus kimenet
2 db analóg bemenet (0-10V v 0-20mA)
2 db analóg kimenet (0-10V v 0-20mA)
Szerelőlapra csavarozható
Teljesítmény: 750W
Kimeneti áram: 2,7A

Expected delivery:
1-2 working days
External stock H2 (1-3 days):
7 db
External stock H2 (1-3 days): 7 db
Nettó: 175.12

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 11KW
Output current: 25A

Expected delivery:
1-2 working days
External stock H2 (1-3 days):
3 db
External stock H2 (1-3 days): 3 db
Nettó: 384.36

Input: 380~ 440Vac, 3 phase
Output: 3 phase (~ 230Vac)
Vector control
RS485 Modbus RTU communication
Built-in EMC filter
6 multifunctional digital inputs
2 programmable relays
1 pulse output
2 analog inputs (0-10V v 0-20mA)
2 analog outputs (0-10V v 0-20mA)
Can be screwed to the mounting plate
Performance: 37KW
Output current: 75A

Expected delivery:
Inquire please!
External stock H2 (1-3 days):
0 db
External stock H2 (1-3 days): 0 db
Nettó: 1 099.24
 